close menu

Freedom Clima

Effective at the lowest water temperatures

Freedom Clima
Reddot Design Award Winner

Effective at the lowest water temperatures

The lower the water temperature, the clearer the benefits of its power and flexibility! It is the perfect solution for use with heat pumps and new heating systems operating at very low water temperatures.

Top performers
Freestanding
En norm
Low water temperature 35 50
High water temperature 55 45
Active cooling
Passive cooling

Elke afmeting, iedere plaats

Dit product is verkrijgbaar in meerdere modellen. Zoek het model met de afmetingen die geschikt zijn voor uw oplossing.

Zoek model

Customize your Freedom Clima

At Jaga, we believe Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua.

Standard colors

Traffic white RAL 9016
.33
Sandblast grey
001

Custom colors

White RAL 9010
.01
Pergamon
.05
Natura
.23
Bahama
.12
Warm brown RAL 070 60 10
.34
Off-white RAL 9001
.02
Traffic yellow RAL 1023
.35
Orange
.36
Flaming red RAL 3000
.11
Ruby red RAL 3003
.26
Agais
.20
Yellow green RAL 110 80 60
.37
Green
.38
English green RAL 6009
.13
Azure
.39
Ocean blue RAL 230 70 30
.40
Sapphire blue RAL 5003
.08
Night blue RAL 5011
.41
Pink
.42
Magenta RAL 010 50 50
.43
Violet RAL 4008
.19
Purple
.44
Classic white
.28
Light grey RAL 7035
.03
Dark grey RAL 7011
.09
Anthracite grey RAL 7016
.31
Black RAL 9005
.04

Sizes & outputs

Afmetingen

Outputs table

Model Height (cm) Length (cm) Type 75/65 ˚C 55/45 ˚C 35/30 ˚C
Standard - - - 984 590 246
Standard - - - 1969 1181 492
Standard - - - 2953 1772 738
Standard - - - 3937 2362 984

Aansluitsets

Met de juiste aansluitstukken kunt u heel wat Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat.

Downloads

Pictures
Freedom - Pictures INT
Brochure
Freedom Clima - Brochure INT
User manual
Freedom Clima - Manual INT
User manual
Freedom Clima - Manual JPDC - INT
Brochure
Jaga Dynamic Product Controller - Brochure INT

Frequently asked questions

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat.

Options

CLOCK THERMOSTAT HEATING / COOLING


  • automatic thermostat
  • day / night and week program
  • room regulator for one room
  • automatic or manual changeover heating/cooling
  • display with background lighting
  • power supply 24 VDC
  • output control 0-10 VDC
  • valve contol 0-10 VDC
  • min. and max. temperature control

JAGA CLOCK THERMOSTAT IN COMBINATION WITH CONTROL FOR MULTIPLE ROOMS


  • automatic thermostat
  • day / night and week program
  • activators: auto / continuous
  • batteries included
  • control of multiple rooms (max. 4 zones)
  • control of the heating installation
  • control of the cooling installation
  • control of three-way valves
  • control of zone valves per room
  • control of fans via 0-10 VDC signal
  • manual adjustment of fan speed
  • indication of the operating mode by means of LEDs
  • for DIN rail mounting
  • to be used with thermostats with volt free contacts (e.g. Jaga clock thermostat 7990.073)
  • screw connectors

POWER SUPPLY

  • for DIN-rail or wall mounting
  • conformity: UL60950 - EN 60950 / Class 2
  • output voltage 24 VDC
  • input voltage 100 - 240 VAC
  • screw connection
  • LED indicator

MAXIMUM CABLE LENGTH

in function of the number of devices: see http://catalogue.theradiatorfactory.com/be#freedo...

Delivery

Fully pre-mounted free-standing radiator consisting of:

  • aluminium casing
  • aluminium cover panels
  • aluminium grilles
  • dynamic heat exchanger with flexible stainless steel connections 1/2”, 15 cm long
  • 24 VDC tangential activator(s), with integrated stainless steel filter
  • hydraulic and electrical connections integrated in the left foot
Connectors

HYDRAULIC CONNECTION

  • the heat exchangers are same-end connection and are Always connected to a two pipe installation on the left hand side, using the stainless steel flexible hoses
  • always install Freedom Clima with the heat exchanger on the window side or on the wall side, not on the room side
  • allow extra space for curtains between the Freedom casing and the window.
  • insulate valve and pipes to prevent condensation when cooling

ELECTRICAL CONNECTION

  • 24 VDC clamp connector for electrical connection on the left, to be connected to an external power supply
  • speedcontrol activator(s) 0-10 V:
  • Jaga room controller (4 zone(s))
  • thermostat (for heating and cooling) with 0-10 VDC output control (1 zone)
  • through home automation 0-10 VDC

Thank you for reaching out. We will be in touch with you soon.

To:

Please get in touch with me through: